Install Double-Walled Vent Pipe

5:28
9:08
2.6K views

At 5:28 in

Helping My Neighbor Install a 50-Gal Rheem Gas Water Heater

What happens here

Install the double-walled vent pipe, which is crucial for safely expelling exhaust gases. The original setup had a 4-inch vent, but a 3-inch double-walled pipe is required by code. An adapter (4x3 adapter) is used to connect the new 3-inch vent to the existing 4-inch vent connection point in the ceiling. Secure the vent pipe segments together and to the water heater's exhaust port using self-tapping screws and seal all seams with aluminum tape to prevent leaks. The bend in the vent pipe should be smooth to maintain proper airflow.

Goal: Safely install the exhaust vent system for the gas water heater.

Tools and materials

  • 4x3 Adapter — Connecting the 3-inch vent pipe to a 4-inch existing connection
  • Aluminum Tape — Sealing vent pipe seams
  • Double-Walled Vent Pipe — Expelling exhaust gases from the water heater
  • Drill / Impact Driver Milwaukee — Driving screws into the vent pipe
  • Self-Tapping Screws — Securing vent pipe segments