Skip to main content

Troubleshoot and Repair Dump Trailer Hydraulics

1:08
14:41
56.3K views

At 1:08 in

Tough, Tight site

What happens here

While attempting to unload more materials, the hydraulic dump trailer malfunctions and will not lower. The operator attempts to use the wired remote control to lower the trailer, but it fails. Upon inspection, it is discovered that a wire has come loose from the hydraulic pump, preventing operation. The wire is reconnected to restore the trailer's functionality.

Goal: Fix a malfunctioning hydraulic dump trailer.

Tools and materials

  • Dump Trailer — The equipment being repaired
  • Hydraulic Pump — The component with the disconnected wire
  • Wired Remote Control — Operating the hydraulic system and diagnosing the issue
  • Electrical Wire — Reconnecting the hydraulic pump

What they say

Hide

realistic trailers not going down so go up can you figure out what's going on with it that looks like it's supposed to be hooked up to something

Auto-generated from the video audio.