Re-tension Track, Fill Fluid & Final Inspection
At 12:59 in
The Cat dies on the job #frickin
What happens here
Once the new hydraulic lines are installed and secured, the track is carefully re-installed onto the skid steer (re-installation process not fully detailed but implied). The track tensioner's grease fitting is then tightened, and a powered grease gun is used to inject grease until the track achieves the correct tension. The 'two-finger' method is demonstrated, where the track should deflect roughly two fingers' width when pressure is applied, indicating proper tension. After tensioning, the hydraulic system is refilled with fresh fluid from buckets. All newly installed and reconnected fittings are wiped down and visually inspected for any signs of dripping or leakage. Any connection showing a leak is further tightened and re-inspected.
Goal: After replacing the hydraulic lines, the track is re-installed and tensioned using a specific 'two-finger' method for optimal performance. The hydraulic system is then refilled with fluid, and all new connections are meticulously checked for any leaks.
Tools and materials
- Compact Track Loader (Skid Steer)
- Powered Grease Gun (e.g
- Milwaukee)
- Wrenches
- Grease Unspecified
- Hydraulic Fluid Unspecified
What they say
(1,284 characters)Hide
What they say
(1,284 characters)Auto-generated from the video audio.