What happens here

To test resistance and continuity, rotate the multimeter's dial to the 'Ω' (Ohms) setting. When the test probes are not touching anything, the display will show 'OL' (Open Loop), indicating infinite resistance. When you touch the red and black probes together, the reading should drop to a value very close to zero, signifying almost no resistance and a complete circuit. Many multimeters will also emit an audible beep when continuity is detected, which is particularly useful for checking components like fuses or wires. If testing a fuse and you hear a beep and get a low resistance reading, the fuse is good. If you hear no beep or get an 'OL' reading, the fuse is blown.

Goal: Measure electrical resistance and check for continuity in a circuit or component.

Tools and materials

  • Automotive Fuse — An example component to test for continuity
  • Black Test Lead — Connecting to the component being tested
  • Multimeter Klein Tools MM400 — Measuring resistance and checking continuity
  • Red Test Lead — Connecting to the component being tested

What they say

Hide

hertz. You can see that's 60 hertz. Ohms measure resistance. With the probes apart, there is no path. If I go ahead and touch them together, there's almost no resistance, and it's going to read close to zero. Continuity uses the same basic idea. This is good for testing things like wire and fuses. Continuity checks whether there's a complete electrical path. If your wire is broken or your fuse is blown, you won't hear the beep at all. And some meters can even tell me if my