What happens here

Carefully insert the new, lubricated cartridge into the valve body. Ensure that the 'top' notch or marking on the cartridge aligns with the corresponding feature on the valve body for correct installation. You may need to remove a metal ring from the new cartridge (if it came with one) and reinstall the old metal retaining ring that was previously removed. Once inserted, the cartridge should fit snugly. Then, secure the metal retaining plate back in place by reinserting and tightening the two brass screws with your screwdriver.

Goal: Place the new cartridge into the valve body and secure it.

Tools and materials

  • Screwdriver Milwaukee — Tightening brass screws
  • Brass Screws — Securing the retaining plate

What they say

Hide

that is going to be the top this one goes back in here like so all the way in we're popping this metal ring right here off we don't need that we're going to be putting our old one back on this one right here we've got the O-rings around the out side we've got them lubed up and now we can just pop that on and that is the way this is going to set right this is a universal valve that's got a bunch of different combinations to it get this pushed in here like so you want to make sure that this top notch right here is lined up the actual top hole is there and we're able to get this tightened on this one as