Adjust Anti-Scald Feature (Optional)

5:55
7:01
53.9K views

At 5:55 in

Fix Your Leaky Kohler Shower: Complete Cartridge Swap Guide

What happens here

If desired, adjust the anti-scald feature on the Kohler valve. This is typically a red knob with an Allen wrench adjustment screw on the cartridge. To allow for more hot water, back the screw out. To limit the maximum hot water temperature (a safety feature useful for households with children or elderly), tighten the screw. This adjustment is performed on the cartridge itself, usually before the handle is fully reinstalled.

Goal: Set desired maximum hot water temperature for safety and comfort.

Tools and materials

  • Allen Wrench — Adjusting the anti-scald screw

What they say

Hide

clear go to rock and roll here's the adjustment for the anti-cold feature for this colar valve it is this red looking knob right here and it has this little allen wrench adjustment screw okay you back this out and then once you close this it will give you more hot water if you had a child or an elderly concern about them getting burned well then just tighten it up and it's not going to allow you to get as much hot water as you potentially

Auto-generated from the video audio.