Remove Rear Housing and Old Needle
1:01
4:28
158.8K views
At 1:01 in
How to Repack or Repair A Graco Airless Spray Gun. Graco airless gun repairs.
What happens here
Next, use the 5/8 inch box wrench to unscrew and remove the spring housing from the back of the gun. Once the housing is off, carefully pull out the old spring and the small retainer. These old parts will be replaced with new ones from the kit. The needle assembly is now exposed. To remove it, use the 9/32 inch socket and crescent wrench to loosen the nut on the side of the gun that secures the pin running through the trigger. After loosening, remove the pin. If the old needle assembly is stuck, pliers can be used to gently pull it out.
Tools and materials
- 5/8 inch Box Wrench
- 9/32 inch Socket
- Crescent Wrench
- Graco Contractor Gun
- Pliers
What they say
(777 characters)Hide
What they say
(777 characters)Auto-generated from the video audio.