Electrical Requirements and Breaker Selection
At 1:16 in
HOW TO INSTALL IYILO 48 AMP HARDWIRED EV CHARGER! | Day in the Life of a Residential Electrician
What happens here
The installer details the electrical requirements for the Level 2 EV charger. A double-pole circuit breaker is essential for the 240V supply. For this specific installation, a 40-amp double-pole Square D QO circuit breaker will be used, given the customer's 100-amp electrical panel and load calculations. The charger can accommodate breakers from 20 amps to 60 amps, allowing for de-rating based on panel capacity. With a 40-amp breaker, the charger will provide a continuous output of 32 amps. The wiring chosen for this installation is 8/2 Romex, which is appropriately rated for a 40-amp circuit.
Goal: Understand the circuit breaker and wiring specifications
Tools and materials
- 8/2 Romex Wire Romex — To supply power from the electrical panel to the EV charger
What they say
(1,006 characters)Hide
What they say
(1,006 characters)Auto-generated from the video audio.