What happens here

With the power OFF at the main breaker, open the electrical panel. Carefully strip the outer jacket off the 6/3 Romex wire using a razor knife or wire stripper to expose the individual conductors (two hot, one neutral, one ground). Install a 40 amp (or 50 amp, as specified for continuous load) GFCI (Ground Fault Circuit Interrupter) breaker into an available slot in the electrical panel. Connect the two hot wires to the GFCI breaker terminals, the neutral wire to the neutral bus bar, and the ground wire to the ground bus bar. Ensure all connections are tight and secure. Finally, attach the provided ChargePoint label to the electrical panel cover to indicate the new circuit.

Goal: Install GFCI breaker and connect new circuit wiring

Tools and materials

  • 40A GFCI Breaker Cutler-Hammer Eaton — Providing circuit protection and ground fault protection for the EV charger circuit
  • ChargePoint Label ChargePoint — Labeling the new circuit in the electrical panel for safety and identification
  • Insulated Gloves — Additional protection when working with live electrical components (though power should be off)
  • Razor Knife — Stripping the outer jacket of the Romex wire
  • Screwdriver Set — Tightening terminal screws on the breaker and bus bars
  • 6/3 Romex Wire — The conductors being connected to the breaker

What they say

Hide

because we need, you know, believe it or not, this wire is pretty thick. So, and uh right now, guys, I'm stripping the wire, the jacket off the ROMX, and I use a razor knife. Guys, my name is Hendy, guys. Hendy the Sparky. And if you guys like this video, can you please throw a like, comment, subscribe, guys, because it would mean the world to me. Anyways, we are now mounting the charge point. And anytime, guys, it's New Jersey code. You have to install a GFCI breaker