Step 8 · Connect Gas Line and Venting (Gas Heaters)
For gas water heaters, connect the gas supply line to the gas control valve on the new unit. Use approved pipe thread sealant suitable for natural gas or propane. Make sure to use a flexible gas connector if required or permitted by local code. After connecting the gas line, reattach the vent pipe (flue) to the draft hood on top of the water heater. Ensure the vent pipe has the correct slope (typically rising towards the chimney or vent termination) and is securely fastened to prevent leaks. Check for any obstructions in the vent pipe. Test all gas connections for leaks using a soapy water solution; bubbles indicate a leak that must be fixed.