Proper Compaction Techniques for Backfill
At 1:09 in
WHY Retaining wall Engineers ARE ALL WRONG!!
What happens here
The presenter highlights the critical importance of proper compaction for the backfill behind the retaining wall. Using a 250-pound plate compactor, he demonstrates compacting in very short 'lifts' (layers) of approximately 2.5 to 3 inches. He explains that compacting deeper lifts (e.g., 4 inches) only compacts the top few inches, leaving the lower portion uncompacted. This leads to future settling and potential wall failure. Achieving actual complete compaction requires these short, controlled lifts. Expert commentary emphasizes that for engineered walls, proper compaction behind the drainage zone is essential to prevent problems, regardless of engineering specifications that might suggest otherwise for 'uncontrolled fill'.
Goal: Understand and apply correct compaction techniques using a plate compactor, emphasizing short lift depths to achieve full compaction and prevent future settling.
Tools and materials
- Plate Compactor (250 lb)
- Drainage Aggregate (Gravel)
What they say
(766 characters)Hide
What they say
(766 characters)Auto-generated from the video audio.