Skip to main content

Test System & Backfill Well Pit

17:49
23:27
177K views

At 17:49 in

the "NO SEE UM" Contractor Scam! PULLED & Released w/NEW UPDATES

What happens here

After the new pressure tank is installed, Tyler from A&T Pump Service tests the well system's pressure at the house's exterior spigot. He adjusts the pressure from the previous 80 PSI to an optimal 60 PSI, which is better for the well's longevity. Once the system is confirmed operational, the crew begins backfilling the excavated area using the mini excavator and a Bobcat, carefully tamping the soil to prevent future settlement.

Goal: The well pressure is tested and adjusted to the correct PSI, then the excavated area is backfilled and graded using heavy machinery.

Tools and materials

  • Bobcat — Grading the backfilled area
  • Mini Excavator Bobcat 325 — Backfilling the well pit
  • Pressure Gauge — Testing well pressure

What they say

Hide

see as much okay so we've got it cranked up to 80 pounds of pressure because we were compensating trying to get it fixed we're gonna turn it down and tyler's got a pressure gauge in his hand do you gotta run that back on the house again tyler okay so he's gonna hook that up to the outside spigot i'll drain some pressure off from it and then we'll see where we're at what are you seeing turned on at about 43. i shut off at 60. [Music] so we're all set so i'll get this wrapped up i'm gonna shovel some dirt onto it just protect it okay i'm gonna shovel a lot of dirt onto it [Music] i'm not compacting this area because i would rather deal with potential settlement down the road than to deal with any issues by over compacting on the pressure tank [Music]

Auto-generated from the video audio.