Install Air Admittance Valve (AAV)
At 11:21 in
Kitchen Makeover + PLUMBING ON CONCRETE (Ep.2)
What happens here
Instead of extending a vent pipe through the roof, an Air Admittance Valve (AAV) is installed. The presenter explains that an AAV allows air into the plumbing system to equalize pressure, preventing slow drains and odors, without releasing noxious sewer gases. Crucially, building codes require AAVs to be a minimum of 4 inches above the highest horizontal drain tube (or in this case, the highest point of the sloped drain before the P-trap). The presenter secures the AAV to the wooden frame, ensuring it meets this height requirement. An access panel is necessary for an AAV in case of failure or maintenance. The valve is attached to a section of ABS pipe using purple primer and ABS adhesive cement.
Goal: An Air Admittance Valve (AAV) is installed as a cost-effective and space-saving alternative to a traditional vent stack, ensuring proper drainage and preventing sewer gas from entering the living space.
Tools and materials
- ABS Adhesive Cement
- Air Admittance Valve (AAV)
- Purple Primer
- ABS Pipe (for AAV connection)
What they say
(990 characters)Hide
What they say