Complete Second Outlet and Verify Installation
3:19
3:54
3K views
At 3:19 in
Installing 2 -20 AMP Outlets in a Detach Garage From SCRATCH!
What happens here
The electrician extends the circuit from the "load" side of the first GFCI outlet to the second outlet location, running the MC cable cleanly above the garage door and across the wall. He installs the second metal electrical box and wires the second GFCI outlet to it, ensuring proper grounding. Finally, he uses a Klein Tools RT250 GFCI Receptacle Tester to verify that both outlets are receiving 120 volts and that their GFCI protection is functioning correctly, confirming a safe and operational installation.
Goal: Install the final outlet, ensure all connections are secure, and verify the circuit's functionality and safety.
Tools and materials
- GFCI Outlet — Second outlet, providing ground fault protection
- Metal Electrical Box — Housing for the second GFCI outlet
- Screwdriver — Connecting wires and mounting the outlet
- Straps/Clamps — Securing the MC cable
- Wire Strippers — Preparing wire ends
What they say
(403 characters)Hide
What they say
(403 characters)Auto-generated from the video audio.