Install Circuit Breaker and Final Panel Connections
6:49
8:52
17.3K views
At 6:49 in
HOW TO INSTALL A TESLA WALL CONNECTOR ANYWHERE! THE EASY WAY!
What happens here
The Romex cable is stripped to expose the individual conductors. The installer then installs a 40 Amp double-pole circuit breaker into the main electrical panel. This may require rearranging existing breakers to make space, potentially by installing a tandem breaker. The ground wire from the Romex is connected to the ground bar in the panel, and the two hot wires (black and red-taped white) are connected to the 40 Amp double-pole breaker. Once all connections are secure and neat, the panel cover is reinstalled.
Goal: Connect the charger circuit to the main electrical panel
Tools and materials
- 40 Amp Double-Pole Circuit Breaker — Protecting the EV charger circuit from overcurrent
- Electrical Panel Cover — Securing the electrical panel
- Razor Knife — Cutting the outer sheathing of the Romex wire
- Screwdriver Wiha — Connecting wires to breaker terminals and securing the panel cover
- Tandem Breaker — To free up space for the new double-pole breaker if needed
- Wire Strippers — Stripping insulation from wires
What they say
(1,020 characters)Hide
What they say
(1,020 characters)Auto-generated from the video audio.