Reassemble Gun Body and Needle Mechanism
At 7:15 in
Cleaning A Graco Contractor II Gun. Repair an Airless Spray Gun.
What happens here
Now, fully reassemble the gun. Slide the handle back onto the gun, aligning the internal pin within its slot. Screw the handle until it is hand-tight, then use the 5/8-inch wrench to fully tighten it securely. Next, lubricate the inside of the gun body with WD-40, focusing on the packing area and any threads. This helps ensure smooth operation and prevents paint from drying and sticking. Drop the cleaned spring back into the gun body. Carefully insert the needle and seat assembly from the back, ensuring it slides smoothly and aligns into its proper position.
Goal: Fully reassemble the gun's main body, including the handle, spring, and needle assembly.
Tools and materials
- 5/8 inch wrench — Tightening the handle
- Graco Contractor II Gun Graco — The spray gun being reassembled
- WD-40 WD-40 — Lubricating internal parts
What they say