Skip to main content

Inspect and Clean Quick Connect

2:13
23:37
425.9K views

At 2:13 in

Breaking in a New Snowplow

What happens here

Once the hydraulic fitting is successfully detached, thoroughly inspect the internal components of both the male and female quick connect parts. The video reveals significant blockages, including ice buildup, dirt, mud, and a small metal shaving. A bent internal part of the male quick connect is also observed. These contaminants and the physical damage are identified as the root cause of the connection failure and leakage. Use a small pick or screwdriver to carefully clean out the debris.

Goal: Disassemble the faulty quick connect to identify the cause of the leak, finding ice, dirt, and a bent internal component.

Tools and materials

  • Detached Hydraulic Quick Connects
  • Small Pick / Screwdriver

What they say

Hide

to that for me will you sam there so let's pull it apart and we'll see if we can get it back together you see whoa whoa whoa look at that so that was what was in there see how bad it is though oh there's all sorts of dirt oh there's that look at that chunk of ice look at that that's the ice and dirt what what is this looks like mud see these threads look over tightened right here but and look at there's some metal we got a metal shearing right here so that's why we weren't getting us getting it too tight and yeah what do we say third time's a charm when we pull back in what is the fourth time them sam because we've already made three trips out here with at some point we got to bring the skid loader to the tools and not the tools to the skid loader

Auto-generated from the video audio.