Align Air Distributor Plate Correctly
At 2:33 in
Fan Control | Troubleshooting Issues With the 77000 Atomizer Spray Gun
What happens here
The key to restoring full fan pattern control is to correctly orient the air distributor plate. The speaker explains the '12 and 6' o'clock rule: the slots on the air distributor plate must be positioned at 12 o'clock and 6 o'clock (vertical alignment) relative to the spray gun. This ensures that the air passages are open, allowing air to be evenly distributed through the air cap's 'ears' and center hole. This even airflow is essential for the fan control ring to effectively shape the spray pattern as intended.
Goal: Orient the air distributor plate so its slots align with the air passages at the 12 and 6 o'clock positions for proper fan pattern control.
Tools and materials
- Air distributor plate
- Fan control ring
What they say
(1,140 characters)Hide
What they say
(1,140 characters)Auto-generated from the video audio.