Identify the leaking section of the 1/2-inch copper pipe. To ensure a clean, perpendicular cut, use a tubing cutter. Place the cutter around the pipe at one side of the damaged area and tighten the knob until the cutting wheel makes contact. Rotate the cutter around the pipe, tightening the knob slightly with each rotation until the pipe is cut through. Repeat this process on the other side of the damage, removing the faulty section. The goal is to create a gap that is slightly shorter than your push-to-connect coupling, allowing you to insert the pipe ends into the fitting.
Step 2/6
Cut Out the Damaged Pipe Section2 min