Change Engine Oil
At 3:49 in
HOW TO SERVICE A 14 KW GENERAC GENERATOR! FULL SERVICE!
What happens here
To facilitate draining, start the generator and let it run for approximately 5 to 10 minutes to warm up the engine oil. This will make the oil less viscous and allow it to drain more smoothly and quickly. Locate the orange oil drain plug/nozzle, typically on the bottom side of the generator. Remove the orange cap and attach a flexible extension tube to the nozzle. Position a small blue drain pan or a suitable container directly underneath the extension tube to catch the old oil. Allow the oil to drain completely. Once drained, remove the extension tube and replace the orange drain plug cap securely. Finally, use a blue funnel to carefully pour the new Generac SAE 5W-20 Full Synthetic Engine Oil into the engine's oil fill port. Periodically check the oil level using the dipstick to ensure the correct amount is added according to the manufacturer's specifications.
Goal: Drain old engine oil and refill with new oil.
Tools and materials
- Blue drain pan — Collecting old engine oil
- Blue funnel — Pouring new oil into the engine
- Flexible extension tube — Directing draining oil
- Oil dipstick — Checking engine oil level
- Orange oil drain plug/nozzle — Point of oil drainage
- Paper towels — Cleaning up spills and wiping the dipstick
What they say
(2,200 characters)Hide
What they say
(2,200 characters)Auto-generated from the video audio.