Proceed to wire the sub panel, following a specific order for safety and code compliance. First, connect all ground wires (typically green or bare copper) to the dedicated ground bar. Next, connect the neutral wires (white wires), ensuring that any black wires used as neutrals are properly marked with white electrical tape. Finally, connect the hot wires (black, red, or other colors) to their respective circuit breakers, installing the breakers into the panel's bus bar. In this instance, 50-amp breakers are installed for the EV chargers and a 30-amp breaker for the generator inlet.
Goal: Connect all electrical circuits and install protective breakers in the sub panel.
Tools and materials
- Circuit Breaker — Providing overcurrent protection for the generator inlet
- Circuit Breakers — Providing overcurrent protection for the EV chargers
- Electrical Tape — Marking non-white wires as neutral conductors
- Ground Wires — Connecting to the ground bar for safety
- Hot Wires — Connecting to the circuit breakers
- Neutral Wires — Connecting to the neutral bar
- Screwdriver — Tightening terminal screws for wires and breakers