Remove and Inspect Needle
At 5:27 in
How to clean & rebuild a Graco Contractor II gun. Graco Sprayer Tips.
What happens here
With the gun disassembled, the old needle can now be removed. Attempt to push the needle out by hand. If it is stuck due to dried paint or wear, carefully use a piece of wood and a hammer to gently tap the needle out of the housing. Be very careful not to scratch the needle if you intend to reuse it, as scratches can cause leaks. The presenter suggests using a wooden paint stir stick for this. Once the needle is out, inspect it and the small rubber O-ring attached to it. The O-ring should be replaced, and the needle can either be cleaned or replaced if damaged. A new needle and housing part typically costs around $55.
Goal: Remove the old needle and inspect components for wear
Tools and materials
- Hammer — Gently tapping out a stuck needle
- Needle
- Piece of Wood — Protecting the needle while tapping it out (e.g., paint stir stick)
What they say
(1,026 characters)Hide