The video clarifies that a correctly built retaining wall should not excessively rely on drain tile for its primary drainage. Instead, the entire wall structure, including its backfill, should be designed to allow water to pass through evenly. If water is seen actively flowing out of a drain tile opening, it indicates that the drainage aggregate behind the wall is likely saturated or improperly installed, concentrating all water pressure onto a small, perforated pipe. This suggests a systemic failure in the overall drainage design, potentially leading to wall failure as the drain tile is meant only as an emergency overflow, not the main drainage mechanism. Proper backfilling allows water to permeate through the wall's face uniformly.