Address Fireplace Installation

6:14
12:30
74.7K views

At 6:14 in

12 Things I Wish I Knew Before Building a House

What happens here

The aggressive 21/12 roof pitch of an A-frame makes fireplace installation complicated. Whether opting for a gas or electric fireplace, a flat section must be framed out against the sloped roof to accommodate it, leading to a loss of valuable livable space. Furthermore, routing the vent pipe through the rafters presents a challenge: energy codes limit the amount of uninsulated rafter exposure (typically no more than 40%) to maintain the R-value of the home. Running a straight vent pipe through the rafters could violate these codes and reduce energy efficiency. While running the pipe vertically to the highest pitch of the roof is an option, it requires careful consideration to avoid compromising insulation. A simpler wall design would mitigate these issues, making fireplace installation much easier.

Goal: Installing a fireplace in an A-frame with a steep roof pitch is challenging, requiring a framed-out flat section (losing space) or careful vent pipe routing that can compromise energy efficiency.

Tools and materials

  • Fireplace (Gas or Electric)
  • Framing Materials
  • Vent Pipe

What they say

Hide

be when it comes to hiring contractors number eight on the list is considering a fireplace with this 2112 aggressive pitch roof and it being a cabin you might consider wanting to have a fireplace to make a more of a cozy atmosphere in the winter time but where would you put that fireplace is it going to be gas or is it going to be electric whichever option you choose you're going to have to build the section flat so you're going to frame it out you're going to lose more livable space in order to fit that in the best solution that we came up to be able to have a fireplace is we're going to go with a gas fireplace that's round and the pipe is going to go up through these Rafters and out outside now I don't like that the vent pipe is going to be sticking out this close to the pitch roof I was considering having a swivel up and come at the highest pitch of the roof the problem with that is with that vent pipe running all through this rafter code regulations for energy requires that you cannot have more than 40% of that rafter exposed and not insulated because that will reduce the R value for the Energy Efficiency of the home again with a simpler wall face here you probably have no issues putting any kind of fire place but with this design these are things you have to come up with number nine on

Auto-generated from the video audio.