Optimize Drainage Zone Depth
At 5:21 in
The #1 MOST SCREWED UP thing on RETAINING WALLS!
What they say
(1,381 characters)Hide
What they say
(1,381 characters)than that i suppose so i'm gonna disagree with sam on this one because we do typically add more than what we're supposed to when our drainage zone let me explain the retaining wall requires 12 inches minimum of drainage rock and the second thing that contractors screw up the most the first thing they screw up the most is they use p rock or the wrong kind of drainage aggregate but the second thing is they don't use enough of it so although the specs for the retaining wall call for a minimum of 12 inches you'll typically see all of our walls doing two foot sometimes even three foot lifts in rock and then we pyramid this massive drainage zone up to where we hit the grid and then it's kind of a reset then the grid goes down and then we go back down to 12 well actually we go wider on top of the grid and then as we come up we pyramid it up so you'll see that our drainage zones act like multiple pyramids laying on top of each other where it's always the very minimum is 12 inches but i have absolutely no qualms going 24 inches sometimes 36 inches and the reason i say that is although it's not bid for that in an earlier video i said my goal is to build retaining walls that last longer than i do and i think getting the right drainage material and not skimping on it are two key components to making that happen good morning everyone last day on our wall so that's kind of
Auto-generated from the video audio.