Install Conduit and Run Wiring

0:28
0:48
17.5K views

At 0:28 in

Installing a NEMA 14-50R Outlet as an EV Charger in a Residential Garage, Thoughts? #ford #ev

What happens here

Run a 3/4 inch Electrical Metallic Tubing (EMT) conduit along the wall, from the installed NEMA 14-50R receptacle box down to the basement, and then to the electrical panel. The video shows a neat conduit run strapped to the wall. Secure the conduit to the wall using appropriate straps and connectors at regular intervals according to code. Once the conduit pathway is complete, pull the correctly gauged electrical wires through the conduit. For a 50-amp circuit, 6-gauge electrical wire (three insulated conductors: two hot, one neutral, plus a bare ground wire) is typically required.

Goal: Route the electrical wiring safely and according to code to the electrical panel.

Tools and materials

  • 3/4 inch EMT Conduit — Protecting and routing electrical wires, Conduit Bender Klein Tools

What they say

Hide

This is a Nema 1450 Ford charger. And this is a J1772 that goes right into the Ford Mustang Mackie. And as you can see, we ran 3/4 inch EMT conduit going on the wall strapped nice, nice and low. And that goes right into the basement and right to the electrical panel. So guys, if you need an EV charger installed, whether it's hardwired or it's plug-in, we got you in New Jersey. All right, see you in