Transition Interior to Exterior Wiring
At 0:49 in
How to make $2000 in 1 Day, Become an Electrician #bluecollar #chargepoint
What happens here
The metal clad cable coming from the basement needs to transition to the exterior PVC conduit. This is achieved using an 'LB' (conduit body), which is an L-shaped fitting that allows the cable to change direction and emerge from the wall into the 3/4-inch PVC conduit. At this transition point, the 6/2 metal clad cable is spliced to individual conductors of '#6 THHN wire,' which stands for 'Thermoplastic High Heat Resistant Nylon' wire. The THHN wires are then pulled through the PVC conduit to the location of the car charger unit.
Goal: Safely transition the interior metal clad cable to exterior THHN wire within the PVC conduit.
Tools and materials
- #6 THHN Wire — The specific type of wire run through the PVC conduit to the charger, designed for high heat resistance and outdoor use
- 3/4-inch PVC Conduit — Housing the THHN wire from the LB conduit body to the EV charger
- 6/2 Metal Clad Cable — The interior wiring that connects to the THHN wire at the transition
- Drill — Drilling a hole through the wall for the LB conduit body
- Electrical Tape — Providing additional insulation and protection for wire splices
- LB Conduit Body — Facilitating the transition of wiring from inside the wall to the exterior PVC conduit
- Wire Nuts/Connectors — Securely joining the metal clad cable to the THHN wires
What they say
(350 characters)Hide
What they say
(350 characters)Auto-generated from the video audio.