Failure Cause 1: Inadequate Block Choice and Connection

0:29
7:44
947.9K views

At 0:29 in

How to Build a Retaining wall (and why they Fail)

What happens here

The speaker identifies the first major cause of failure: the choice of block type and its connection method. Many landscapers opt for cheaper, hollow blocks that are quick to install. These blocks are characterized by being solid on top but hollow on the bottom, often relying on a simple 'lip' system for connection rather than more robust pins. This design flaw allows water to become trapped inside the hollow cavities. When exposed to freeze-thaw cycles, this trapped water expands and contracts, generating significant pressure that can push the blocks out of alignment. The simple lip connection offers inadequate mechanical resistance against ground movement and frost heave, leading to structural instability and eventual collapse.

Goal: Learn why hollow blocks with a simple 'lip' connection fail.

Tools and materials

  • Hollow retaining wall blocks — Demonstrating inadequate block design and a weak 'lip' connection method
  • Solid retaining wall blocks Versa-Lok — Illustrating a superior, mechanically connected block system like the Versa-Lok standard unit

What they say

Hide

and they tend to be hollow and have a lip on the back and they're solid on the top and then they're hollow on the bottom and what happens is water can get trapped in there between the cavity and it has nowhere to go and then it goes through a freeze-thaw cycle it expands contracts and it pushes the blocks over they also have an inadequate pinning system so instead of they're solid on the top hollow on the bottom because they're light they're easy to pick up and they're fast you see they have their connection method is this lip right here this lip connects the block to the block below it so let's look here let's look behind this wall having pins that you drive down and through the blocks they just rely on a little tiny lip on the back of the block they place the block on top and then they simply slide it forward until this lip touches the back of the block once it touches it's hands off and you're done it's as simple as that there's no pins there's no mechanical connection method to keep this block from moving anywhere else other than the weight of the block itself what happens is that lip as soon as it experiences a little bit of ground movement a freestyle cycle or maybe an earthquake or something else it pushes up it pushes over and now there's nothing connecting it to the block below and that's where these blocks fail because they're hollow remember they're hollow on the bottom side so they're lighter i want you to see something here this is what happens behind the blocks look at right there little pan in a little bit the blocks lift up because there's no mechanical methods as the ground moves the blocks which are right there perfectly fine get forced up and over and now just that lip isn't even holding them anymore

Auto-generated from the video audio.