Perform Continuity Checks on Control Wiring and Fuses
At 6:34 in
FAIL! Bobcats New Electric Skid steer Freezes during demo! 4K
What happens here
After ensuring the machine is completely de-energized and locked out, switch the multimeter to continuity mode (often indicated by a beep symbol). Test individual wires in control circuits (e.g., from operator controls to the main controller, or between controllers) as identified in the schematics. A lack of continuity indicates an open circuit, which could be a broken wire or a faulty switch. Test all relevant fuses; a blown fuse will show no continuity. Also, check the continuity of safety interlock switches (e.g., seat sensor, boom position switches) in their activated and deactivated states to confirm proper operation and ensure they are not intermittently failing or stuck open, which could cause unexpected shutdowns or 'resets'.
Goal: With all power disconnected, use the multimeter in continuity mode to test critical control wiring, safety switches, and fuses. This will detect open circuits or breaks in the electrical path.