Diagnose Water Ingress in Connectors
At 2:12 in
Are Ford's 7.3 Godzillas Disintegrating?? 4K
What happens here
Upon closer inspection of the electrical connectors attached to the hydraulic valve, the worker discovers residual water inside the plugs. He explains that water ingress leads to shorting, causing fuses to blow and the valve to fail. He confirms water in multiple connectors and suggests that the design of the loader allows water to easily splash into these exposed electrical components. He dries out the connector with a cloth and blows air into it to clear any remaining moisture.
Goal: The worker identifies water within the electrical connectors of the hydraulic valve as the cause of the shorting, noting that the design allows water to splash upwards into them.
Tools and materials
- Cloth
What they say
(1,227 characters)Hide
What they say
(1,227 characters)Auto-generated from the video audio.